Home » R&D Center

R&D

 
Diesel power generators have become an essential part of power systems for residential, commercial, and industrial applications. The demand for reliable and efficient generators continues to grow, and manufacturers are always researching and developing innovative ways to improve their production technologies.

At our company, we have been at the forefront of diesel power generator production technology for many years. Our state-of-the-art production facilities enable us to produce high-quality generators with outstanding performance and reliability.

We use advanced manufacturing processes and modern technology to ensure that our generators meet and exceed industry standards. Our team of highly skilled engineers and technicians work tirelessly to guarantee that every generator that leaves our facility is of exceptional quality.

We use only the best materials and components in the production of our generators. From the engine to the alternator, and every other part of the generator, we ensure that they are of the highest quality. Our rigorous quality control measures ensure that each component is tested and checked to guarantee that they meet our exacting standards.

Our diesel power generators provide high-output power, long run-time, and rugged dependability. They are designed to operate efficiently and reliably in extreme conditions, making them ideal for applications that require continuous and uninterrupted power.

In conclusion, our diesel power generator production technology is second-to-none. Our commitment to excellence in production technology, superior quality materials, and stringent quality control measures results in generators that provide long-lasting performance, dependability, and value.

Briefly introduce the composition and working principle of diesel generator sets:
1.Composition of diesel generator set: Diesel generator set is an electromechanical integrated equipment, consisting of several major components such as diesel engine, generator, control system, cooling system, and steel base.
2.Working principle of diesel generator set: The diesel engine converts the thermal energy generated by diesel combustion into mechanical energy, which drives the stator of the generator to rotate and converts it into electrical energy output through electromagnetic induction. The control system monitors, controls, and distributes the electrical energy output by the generator to ensure the normal operation of the diesel generator set.

Maintenance of diesel generator sets:
1. Clean the outer surface of the diesel generator set and the outside of the trailer and engine room. Check the tire pressure of the trailer, check if the connecting bolts of the trailer body are loose, and check if the bolts of the low-noise speaker are loose. Whether the smoke exhaust and air intake and exhaust are smooth.
2. Check if the fuel level in the diesel tank is sufficient (fuel should be sufficient to run 8-12 Hours). Check for fuel leaks and regularly replace the diesel filter.
3. Check the tension of the fan belt and the charger
belt, and make necessary adjustments. Check if the machine bolts are loose. Check the oil level of the diesel engine. Do not operate the diesel engine when the oil level is below the low "L" or above the marked "H".
4. Check for oil leaks, check if the oil filter meets the requirements, and replace the oil filter regularly.
5. Start the diesel engine and visually inspect for oil leakage during operation. Listen for any abnormal noises from the machine
6. Check if the instrument readings, temperature, and loudness displayed during the operation of the diesel engine are normal, and keep monthly operation records.
7. Check if the antifreeze is sufficient and if there are any leaks.
8. Regularly replace the antifreeze, engine oil, and triple filter.
9. Check the air filter, replace or clean it once a year, and check if the intake and exhaust pipes are smooth.
10. Check and lubricate the fan pulley bearings and belt tension shaft. Check the lubricating oil level of the overspeed mechanical protection device and add oil if it is insufficient. Check the tightening of the external main connection bolts.
11. Check the battery voltage and check if the battery connections are loose or corroded.
12. Simulate and test the performance of various safety protection devices, operate at constant load, and check the operation status. During operation, check whether the output voltage meets the requirements, whether the frequency meets the requirements, whether the water temperature and oil pressure meet the requirements during operation, whether the exhaust pipe and muffler are leaking, and whether there is severe vibration and abnormal noise.
13.Check whether the indicators of each instrument and signal light are normal, whether the switch action is normal, and whether the monitoring alarm is normal.
14. Record the operating time of the diesel generator and regularly clean the bottom of the fuel tank. After running for 250 hours:
(1) Replace the diesel fine filter element and engine oil.
(2) Check the tightness of the cylinder head bolts and connecting rod bolts.
(3) Check and correct the valve clearance, test and adjust the fuel injection pressure.